AGD650 troubleshooting checklist

Detector Not Detecting Vehicles

Check:

  • Mounting height is between 3m and 6m.
  • Detector is correctly aligned.
  • Detection zones are configured.
  • Stop line is visible.
  • No obstructions exist in the field of view.

Cannot Connect via WiFi

Check:

  • Blue WiFi LED is illuminated.
  • Correct SSID selected.
  • Correct password entered.
  • Browser is pointed to:

Red LED Remains On

Possible causes:

  • No detection zones configured.
  • Detector still in setup state.

Detector Does Not Boot Correctly

Check:

  • Supply voltage is present.
  • Earth connection is fitted.
  • Power source can support startup current.
  • Red LED flashes 5 times during startup.