Skip to content
  • There are no suggestions because the search field is empty.

How do I configure bus-only detection with the AGD650?

Purpose

Bus-only detection allows outputs to activate exclusively for buses.

Configuration Procedure

  1. Open Set Zones.
  2. Select the required zone.
  3. Open Detection Classes.
  4. Choose Custom.
  5. Select Buses.
  6. Apply settings.

Performance Recommendations

Ambient Lighting

Minimum recommended illumination:

  • 20 Lux

The AGD650 includes an IR filter and does not use IR illumination.

Detector Position

Avoid installations where:

  • Signal heads obscure vehicles.
  • Large objects enter the field of view immediately after the detection zone.

Detection Zone Placement

For best classification accuracy:

  • Position zones 10–20 metres from the detector.
  • Maintain clear visibility before and after the zone.

Vehicle Visibility

The entire vehicle should remain visible while travelling through the zone.

Partial visibility may cause:

  • Reduced confidence scores.
  • Incorrect classification.